Compare Post an RFQ

Product decision guide · Cartesian robots

STAW-1100 Injection Molding Robot

STAW-1100: interpret the published 8 kg load, 1100 mm vertical travel and press range alongside installation, tooling and acceptance requirements.

Manufacturer data with selection guidance for buyers.

Payload8 kg
Vertical stroke1100 mm
Crosswise stroke710 mm
Traverse stroke1600 mm

Manufacturer data

Published specifications

STAW-1100 is a SHIP telescopic Cartesian extraction robot listed for injection-moulding applications. Its official table states 8 kg maximum load, 1100 mm vertical and 710 mm crosswise travel, and a 200-400 ton press screening range. Confirm the exact mounting drawing, full tooling load, machine interlocks and representative extraction trial before ordering. The illustration is for the family; catalog timing does not establish a completed production cycle.

Payload
8 kg
Vertical stroke
1100 mm
Crosswise stroke
710 mm
Traverse stroke
1600 mm

Values and units are shown as the manufacturer publishes them. Confirm the fit for your complete cell with the manufacturer.

A compact extraction layout

Evaluate this model against the opened mould and the required discharge point. The published 1,100 mm vertical travel and 1,600 mm traverse are linear strokes, not articulated-arm reach. Its 200–400 ton press range is a first screening clue; tie-bar spacing, mould height and the robot mounting interface decide whether a particular press can accept it. Compared with STAW-1300, this record has the same stated 8 kg load but less vertical and traverse travel. Choose the shorter arrangement only after checking the deepest pickup pose with the complete gripper.

Record scope: [S1]

The published values and what they mean

The published values and what they mean: questions to resolve in the proposal
Published item / decisionHow to use itLimit to confirm
Maximum load8 kgSupplier table; attached tooling, moments and motion conditions require approval.
Press screening range200-400 tonNot a machine-specific compatibility approval.
Vertical / crosswise travel1100 / 710 mmLinear strokes, not arm radius.
Traverse travel1600 mmCheck the actual release point and guarding.
Arm / drivetelescopic / X.Y.Z AC ServoConfirm controller and ordered servo arrangement.
Posture90°Catalog label; posture mechanism and axis-count definition need confirmation.
Minimum take-out1.5 secondsCatalog minimum, not a complete measured production cycle.
Air / electrical supply0.5Mpa / AC220VConfirm inlet requirements, protection, electrical load and installation circuit.
Air usage1.5 nlMeasurement conditions and cycle basis are not defined on the page.
Net mass360 kgInstallation reactions and foundation requirements remain separate.

Record scope: [S1]

Resolve this model’s installation questions

Record scope: [S1]

Turn the take-out claim into a test

The catalog quotes 1.5 seconds minimum take-out, not a completed injection-moulding cycle. Measure time from the agreed mould-open signal to the robot-clear signal with the representative part and tool.

Agree on the mould-open, robot-entry, gripping, mould-clear and placement events in the controller log. Include stops, rejected parts and manual interventions in any capacity measurement. The source does not establish absolute positioning accuracy, repeatability, safety integrity level or a certified robot–press interface.

Record scope: [S1]

Freeze the machine and handover scope

  1. Identify the press, mould, open gap, ejector sequence, discharge point and ordered robot mounting drawing.
  2. Agree on the loaded tool drawing, fixture retention, vacuum or grip monitoring and fault recovery before a trial.
  3. Document press–robot interlocks, access protection, stopping behaviour and permitted manual recovery for the complete cell.
  4. Run the representative extraction sequence and archive event logs, accepted/rejected counts and agreed acceptance limits.
  5. Receive wiring, pneumatic, mechanical and controller backup documents, maintenance intervals, spare-part responsibilities and installation support terms.

Record scope: [S1]

What should remain open in the quotation?

Is the picture the exact ordered robot?

The image illustrates the STAW family. A signed model-specific configuration drawing and accessory list should govern the order, not the shared illustration.

Does the press tonnage range guarantee fit?

No. Nominal clamping tonnage does not define mould geometry, mounting interface, tooling clearance or safety integration. Check the particular press and mould.

Are price, cycle savings or safety certification verified?

No such result is asserted here. The table is supplier-published information and the checks are platform procurement guidance. No independent test, expert sign-off or certificate verification is claimed.

Record scope: [S1]

Configuration worksheet

A model-specific worksheet has not been reviewed for this record. Use the inquiry outline to request the configuration and acceptance data.

Make the next conversation useful

Your inquiry checklist

Use the model-specific questions above to prepare one consistent brief. The checked items are temporary notes on this page; they are not submitted or saved to an account.

The carry button temporarily keeps your outline in this browser tab for up to two minutes and consumes it on the matching form. Nothing is sent until you submit the form.

Add this product to a specification comparison →

Sources and check dates

[S1] SHIP STAW official model table and dimension sheet

Manufacturer publication · Source reviewed

Exact STAW-1100 row and published family dimensions; merged table cells expanded from DOM rowspan. Supplier claims only, no independent performance trial.

Background guides explain the equipment type in general. For this model, request current configuration documents, commercial scope and an application trial. How profiles are reviewed · Buyer questions

Other published products from this manufacturer

Share this page

Choose a service or copy the link to share.