Compare Post an RFQ

Product decision guide · Cartesian robots

STDW-2200 Injection Molding Robot

STDW-2200: interpret the published 35 kg load, 2200 mm vertical travel and press range alongside installation, tooling and acceptance requirements.

Manufacturer data with selection guidance for buyers.

Payload35 kg
Vertical stroke2200 mm
Crosswise stroke1700 mm
Traverse stroke3080 mm

Manufacturer data

Published specifications

STDW-2200 is a SHIP telescopic Cartesian extraction robot listed for injection-moulding applications. Its official table states 35 kg maximum load, 2200 mm vertical and 1700 mm crosswise travel, and a 1300-2500 ton press screening range. Confirm the exact mounting drawing, full tooling load, machine interlocks and representative extraction trial before ordering. The illustration is for the family; catalog timing does not establish a completed production cycle.

Payload
35 kg
Vertical stroke
2200 mm
Crosswise stroke
1700 mm
Traverse stroke
3080 mm

Values and units are shown as the manufacturer publishes them. Confirm the fit for your complete cell with the manufacturer.

Large-press extraction with a mounting review

STDW-2200 is listed for a 1,300–2,500 ton injection-moulding press range, with 35 kg maximum load and 1,500 kg robot net mass. Its 2,200 mm vertical, 1,700 mm crosswise and 3,080 mm traverse travel should be checked as three separate layout constraints. The larger quoted load does not approve an offset multi-cavity tool: tooling moments, acceleration and the part-release sequence still need supplier review. Discuss press-top support, installation access and lifting arrangements before agreeing on the delivered configuration.

Record scope: [S1]

The published values and what they mean

The published values and what they mean: questions to resolve in the proposal
Published item / decisionHow to use itLimit to confirm
Maximum load35 kgSupplier table; attached tooling, moments and motion conditions require approval.
Press screening range1300-2500 tonNot a machine-specific compatibility approval.
Vertical / crosswise travel2200 / 1700 mmLinear strokes, not arm radius.
Traverse travel3080 mmCheck the actual release point and guarding.
Arm / drivetelescopic / X.Y.Z AC ServoConfirm controller and ordered servo arrangement.
Posture90°Catalog label; posture mechanism and axis-count definition need confirmation.
Minimum take-out3.0 secondsCatalog minimum, not a complete measured production cycle.
Air / electrical supply0.5Mpa / AC220VConfirm inlet requirements, protection, electrical load and installation circuit.
Air usage6 nlMeasurement conditions and cycle basis are not defined on the page.
Net mass1500 kgInstallation reactions and foundation requirements remain separate.

Record scope: [S1]

Resolve this model’s installation questions

Record scope: [S1]

Turn the take-out claim into a test

The 3.0-second minimum take-out claim is not a complete large-part cooling and moulding cycle. Define the measurement window and document safe extraction with the chosen part, tool and acceleration settings.

Agree on the mould-open, robot-entry, gripping, mould-clear and placement events in the controller log. Include stops, rejected parts and manual interventions in any capacity measurement. The source does not establish absolute positioning accuracy, repeatability, safety integrity level or a certified robot–press interface.

Record scope: [S1]

Freeze the machine and handover scope

  1. Identify the press, mould, open gap, ejector sequence, discharge point and ordered robot mounting drawing.
  2. Agree on the loaded tool drawing, fixture retention, vacuum or grip monitoring and fault recovery before a trial.
  3. Document press–robot interlocks, access protection, stopping behaviour and permitted manual recovery for the complete cell.
  4. Run the representative extraction sequence and archive event logs, accepted/rejected counts and agreed acceptance limits.
  5. Receive wiring, pneumatic, mechanical and controller backup documents, maintenance intervals, spare-part responsibilities and installation support terms.

Record scope: [S1]

What should remain open in the quotation?

Is the picture the exact ordered robot?

The image illustrates the STDW family. A signed model-specific configuration drawing and accessory list should govern the order, not the shared illustration.

Does the press tonnage range guarantee fit?

No. Nominal clamping tonnage does not define mould geometry, mounting interface, tooling clearance or safety integration. Check the particular press and mould.

Are price, cycle savings or safety certification verified?

No such result is asserted here. The table is supplier-published information and the checks are platform procurement guidance. No independent test, expert sign-off or certificate verification is claimed.

Record scope: [S1]

Configuration worksheet

A model-specific worksheet has not been reviewed for this record. Use the inquiry outline to request the configuration and acceptance data.

Make the next conversation useful

Your inquiry checklist

Use the model-specific questions above to prepare one consistent brief. The checked items are temporary notes on this page; they are not submitted or saved to an account.

The carry button temporarily keeps your outline in this browser tab for up to two minutes and consumes it on the matching form. Nothing is sent until you submit the form.

Add this product to a specification comparison →

Sources and check dates

[S1] SHIP STDW official model table and dimension sheet

Manufacturer publication · Source reviewed

Exact STDW-2200 row and published family dimensions; merged table cells expanded from DOM rowspan. Supplier claims only, no independent performance trial.

Background guides explain the equipment type in general. For this model, request current configuration documents, commercial scope and an application trial. How profiles are reviewed · Buyer questions

Other published products from this manufacturer

Share this page